About Zones
Zone data in a Conventional Group, LTR Trunking System or NXDN Trunking System can be configured using KPG-111D/
DN.
In addition, zone data in a Conventional Group and zone data for Site Roaming and Site Roaming with RAN can be
configured as an NXDN Conventional system zone. (Refer to
 Conventional Group (Analog Conventional System/ NXDN Conventional System)
A zone in an Analog Conventional system consists of Conventional Channels that are used for communicating in
analog mode.
A zone in an NXDN Conventional system consists of Conventional Channels that are used for communicating in digital
mode using the NXDN protocol.
 LTR Trunking System
This zone consists of GIDs used for communicating using the LTR (Logic Trunked Radio) Trunking protocol.
 NXDN Trunking System
This zone consists of GIDs used for communicating using the NXDN protocol.
The transceiver can be used in Single System or Multiple Systems.
Single System:
Only a single system can be used.
Multiple Systems:
The system to be used can be configured for each zone by selecting from system 1 to 8. A system can be switched
just by changing a zone.
 Site Roaming
This zone consists of channels in an NXDN Conventional system in which Site Roaming is enabled.
 Site Roaming with RAN
This zone consists of channels in an NXDN Conventional system in which Site Roaming is enabled.
For NX-200/ NX-210/ NX-300/ NX-410/ NX-411/ NX-700/ NX-700H/ NX-800/ NX-800H/ NX-900/ NX-901, a maximum of
128 zone data for Conventional Group, LTR Trunking System, NXDN Trunking System, Site Roaming and Site Roaming
with RAN in total can be configured for the transceiver. A maximum of 250 channels or GID data per zone can be
configured for the transceiver. A maximum of 512 channels or GID data can be configured for a transceiver in total.
For NX-200S/ NX-300S, a maximum of 4 zone data for Conventional Group, LTR Trunking System, NXDN Trunking
System, Site Roaming and Site Roaming with RAN in total can be configured for the transceiver.
A maximum of 16 channels or GID data per zone can be configured for the transceiver. A maximum of 64 channels or GID
data can be configured for a transceiver in total.
Note
• The number of zones that can be configured varies depending on the number of channels or GIDs and repeaters.
• The number of channels or GIDs that can be configured for each zone varies depending on the number of zones and repeaters.
FUNC (K)/Ver 4.00
8.14 Site Roaming on page
CONTENTS
173.)
INDEX
xiii

Advertisement

Table of Contents
loading

Table of Contents