Sending The Received Status Message From The Communication Port (Status Message Serial Output); Power-On Status Message; Power-Off Status Message; Status List - Kenwood NEXEDGE NX-200 Function Reference

Hide thumbs Also See for NEXEDGE NX-200:
Table of Contents

Advertisement

12 FleetSync
12.6 Sending and Receiving a Status Message (Status Call)
Sending the Received Status Message from the Communication Port
(Status Message Serial Output)
Status Message Serial Output allows the transceiver to send a Status, and the caller's Fleet and ID, from the transceiver's
communication port when the transceiver receives a Status Message.
The dispatcher can retrieve the transceiver's status information using a PC.
Configuration using KPG-111D/ DN
Configuring the Status Message Serial Output to be enabled or disabled (

Power-on Status Message

Power-on Status Message allows the transceiver to send the selected Status Message when the transceiver is turned ON.
Using the Power-on Status Message, the base station can recognize that the transceiver has been turned ON. The
transceiver sends the message to the FleetSync ID configured for Target Fleet/ID.
Configuration using KPG-111D/ DN
Configuring the Power-on Status Message (

Power-off Status Message

Power-off Status Message allows the transceiver to send the selected Status Message when the transceiver is turned OFF.
Using the Power-off Status Message, the base station can recognize that the transceiver has been turned OFF. The
transceiver sends the message to the FleetSync ID configured for Target Fleet/ID.
Configuration using KPG-111D/ DN
Configuring the Power-off Status Message (

Status List

Status Message must be preconfigured in the transceiver using KPG-111D/ DN prior to the transmission. A maximum of 90
statuses can be configured in the Status List.
Status List can be configured by using KPG-111D/ DN.
Configuration
The Status number can be configured. The Status Number can be configured by using a number between 10
Status
and 99.
The Status number can be configured. It is not easy to recognize the meaning of a status only by viewing a status
Status Name
number. In this case, a user can link the status number to a short message; hence, it can be easily understood. A
maximum of 16 characters can be configured.
The transmission to the receiving party can be enabled or disabled.
The status for which "Yes" is configured for Transmit Inhibit does not appear on the status selection display in
Transmit Inhibit
Status Mode. In this case, a user cannot select a status for which "Yes" is configured for Transmit Inhibit in Status
Mode.
Configuration using KPG-111D/ DN
Configuring the Status List (
FUNC (K)/Ver 4.00
See
FPRG 8.16.7 Target Tab)
See
FPRG 8.16.7 Target Tab)
Table 12-15 Status List
FPRG 8.16.6 Status List Tab)
See
FPRG 8.10.6 Common Page 4 Tab)
See
Description
CONTENTS