10 ANALOG CONVENTIONAL SYSTEM
10.4 Using 2-tone to Initiate a Selective Call
 Transpond/ Alert Tone
Transpond and Alert Tone are functions that allow the transceiver to transmit the multiplexed Transpond tone, or that
allow an Alert Tone to sound from the transceiver when the transceiver is called with 2-tone signaling.
Transpond
No
Yes
No
Anything other than Off
Yes
Anything other than Off
 Alert Tone
Alert Tone is an alert tone to sound when the transceiver receives a call by 2-tone.
The tone can be selected from 8 tones configured in the Alert Tone Pattern. (Refer to
Tone Pattern) on page
91.)
Configuration using KPG-111D/ DN
Configuring the Call Format, the Transpond and the Alert Tone (
(2-tone 4) Tabs)
Frequencies for Standby Code (A Tone/ B Tone/ C Tone/ D Tone)
This function can be used to select the tone frequency for A Tone, B Tone, C Tone and D Tone. The frequency can be
configured between 288.5 Hz and 3106.0 Hz inclusive.
Configuration using KPG-111D/ DN
Configuring the A Tone/ B Tone/ C Tone/ D Tone (
Auto Reset Timer
Auto Reset Timer allows you to configure the amount of time from when the received 2-tone code matches the 2-tone code
preconfigured for the transceiver until the matching status is automatically reset.
Auto Reset Timer can be configured using KPG-111D/ DN. Also, how the transceiver behaves after the amount of time
configured for Auto Reset Timer elapses can be configured.
Configuration
Off
Auto Reset Timer will not be activated.
1 s to 300 s
After the configured time elapses, the matching state of the 2-tone code is automatically reset.
If this function is enabled, the blinking orange BUSY LED for the Selective Call Alert LED turns Off when the time
LED
configured for the Auto Reset Timer elapses.
While this function is enabled, the intermittently emitted Alert Tone stops if the amount of time configured for
Alert
Auto Reset Timer elapses.
While this function is enabled, the matching state of the 2-tone code is reset if the amount of time configured for
Monitor
Auto Reset Timer elapses.
Note
For NX-200S/ NX-300S, the Monitor configuration explained above is always enabled.
FUNC (K)/Ver 4.00
Table 10-9 Transpond/ Alert
Alert
Off
No function is activated.
Off
The transceiver transmits the Transpond Tone.
An Alert Tone sounds from the transceiver.
An Alert Tone sounds from the transceiver after transmitting a Transpond Tone.
See
Table 10-10 Auto Reset Timer
Description
FPRG 8.15.2 Decode (2-tone 1) to Decode
See
FPRG 8.15.2 Decode (2-tone 1) to Decode (2-tone 4) Tabs)
Description
CONTENTS
Configuring the Alert Tone (Alert
INDEX