13 MDC-1200
13.2 Transceiver Behavior in Emergency Mode
At 1 second
intervals
At 1 second
intervals
NX-200/ NX-210/ NX-300/ NX-410/ NX-411
Mobile
Upon the elapse of the time configured for Auto Reset Timer or by a user pressing one of the keys of the transceiver, the
main display reverts to the channel or GID display.
Alert Tone
An Alert Tone sounds from the transceiver only if the transceiver receives an Emergency Alarm Request message.
Upon the elapse of the time configured for Auto Reset Timer or by a user pressing one of the keys of the transceiver, an
Alert Tone stops sounding.
An Alert Tone does not sound from the transceiver even if the transceiver receives an Emergency ID in the MDC-1200
format.
Horn (Mobile Only)
The Horn Alert port is activated only if the transceiver receives an Emergency Alarm Request message. The transceiver
behaves according to the configuration for Horn Alert by using KPG-111D/ DN. (Refer to
23.2 Controlling Car Behavior by
Linking with the Horn Alert Port State (Horn Alert) on page
493.)
The Horn Alert port is not activated even if the transceiver receives an Emergency ID in the MDC-1200 format.
Configuration using KPG-111D/ DN
Configuring the Emergency Response (
FPRG 8.18.2 General Tab)
See
FUNC (K)/Ver 4.00