Kenwood NEXEDGE NX-200 Function Reference page 517

Hide thumbs Also See for NEXEDGE NX-200:
Table of Contents

Advertisement

22 FUNCTION PORTS
22.2 D-sub 25-pin Connector (Mobile Only)
Data PTT
Data PTT is the transmission request port for data communications.
The transceiver migrates to a Data Zone-channel or GID to start the transmission when the Data PTT port goes low level.
The transceiver ends transmitting if the Data PTT port goes high level. The transceiver remains on the data channel for the
amount of time configured for the Data Dwell Time after the Data PTT port goes high level. The transceiver restores to the
voice channel after the amount of time configured for Data Dwell Time elapses.
The relationship between the channel or GID which has its Data PTT port activated and the Data Zone-channel or GID is
shown as below.
Current Channel or GID
Conventional Zone-channel (Analog)
Conventional Zone-channel (NXDN)
LTR Trunking Zone-GID
NXDN Trunking Zone-GID
Also, functions that are used for transmitting by using the Data PTT port can be configured using KPG-111D/ DN. (Refer to
Functions Used for Sending by Using the External PTT (Voice), External PTT (Data) and Data PTT Ports on page
Note
• Data PTT, External PTT (Voice) and External PTT (Data) ports cannot be used at the same time.
• The transceiver mutes the speaker on a data channel or data GID. The transceiver does not send the PTT ID even if the PTT ID is
configured.
CH/GID Select A to CH/GID Select D
CH/GID Select is the CH/GID Select port to be used with the Remote CH/GID List.
The Zone-channel or GID of the transceiver can be changed using the external device that is connected to the transceiver.
(Refer to
Migrating to a Zone-channel or GID by Using a Connected External Device (Remote Zone-CH/GID) on page
490.)
FUNC (K)/Ver 4.00
Table 22-5 Data PTT
The transceiver migrates to an analog channel or GID configured for Data Zone-CH/GID
(Analog) in the Conventional Zone to start transmitting.
If no Data Zone-channel or GID (Analog) is configured, the transceiver will migrate to the data
channel (Channel Type = Analog only) configured for the highest channel number in the zone
to start transmitting.
The transceiver migrates to an analog channel or GID configured for Data Zone-CH/GID
(Analog) in the Conventional Zone to start transmitting.
If no Data Zone-channel or GID (Analog) is configured, the Key-entry Error Tone sounds from
the transceiver and the transceiver does not start transmitting.
The transceiver migrates to an analog channel or GID configured for Data Zone-CH/GID
(Analog) in the LTR Trunking Zone to start transmitting.
If no Data Zone-channel or GID (Analog) is configured, the transceiver will migrate to the data
GID configured for the highest GID number in the zone to start transmitting.
The transceiver migrates to an analog channel or GID configured for Data Zone-CH/GID
(Analog) in the NXDN Trunking Zone to start transmitting.
If no Data Zone-channel or GID (Analog) is configured, the Key-entry Error Tone sounds from
the transceiver and the transceiver does not start transmitting.
Transceiver Behavior
CONTENTS
489.)
INDEX
483

Advertisement

Table of Contents
loading