WAGO-I/O-SYSTEM 750
750-882 Media Redundancy ETHERNET Controller
Table 163: Register Address 0x2033
Register address 0x2033 (8243
Value
Access
Description
Table 164: Register Address 0x2040
Register address 0x2040 (8256
Value
Access
Description
Table 165: Register Address 0x2041
Register address 0x2041 (8257
Value
Access
Description
Table 166: Register Address 0x2042
Register address 0x2042 (8258
Value
Access
Description
Table 167: Register Address 0x2043
Register address 0x2043 (8259
Value
Access
Description
) with a word count of up to 65
dec
Description of the connected I/O modules
Read modules 193 ... 255
Length 1...63 words
The node configuration can be specified in the 0x2033 register. The item number
of the I/O modules or fieldbus coupler/controller (without leading 750) is listed in
order. Because order numbers cannot be read out of digital modules, a code is
displayed for them, as defined below:
Bit position 0
Bit position 1
Bit position 2...7
Bit position 8...14
Bit position 15
)
dec
Implement a software reset
Write (Write sequence 0xAA55 or 0x55AA)
The fieldbus coupler/controller performs a restart by writing the values 0xAA55 or
0x55AA.
)
dez
Flash format
Write (Write sequence 0xAA55 or 0x55AA)
The file system Flash is again formatted.
)
dez
Extract data files
Write (Write sequence 0xAA55 or 0x55AA)
The standard files (HTML pages) of the Coupler/Controller are extracted and
written into the Flash.
)
dez
0x55AA
Write
Factory settings
The default settings are applied after the next reset, e.g., software reset via
MODBUS register address 0x2040.
Fieldbus Communication 259
Input module
Output module
Not used
Module size in bits
Designation digital module
Manual
1.5.0