WAGO-I/O-SYSTEM 750 XTR
750-352/040-000 FC ETHERNET G3 XTR
Table 140: Register Address 0x2031
Register address 0x2031 (8241
Value
Access
Description
Table 141: Register Address 0x2032
Register address 0x2032 (8242
Value
Access
Description
Table 142: Register Address 0x2033
Register address 0x2033 (8243
Value
Access
Description
Pos : 94.49 /Serie 750 ( WAGO-I/O-SYST EM)/Funkti onsbesc hrei bung/F eldbus kommuni kation/M ODBU S/Z ugriff auf R egister werte - Konfigurationsregister 0x2040 @ 4\mod_1235636434734_21.doc x @ 27821 @ @ 1
Table 143: Register Address 0x2040
Register address 0x2040 (8256
Value
Access
Description
Pos : 94.50 /Serie 750 ( WAGO-I/O-SYST EM)/Funkti onsbesc hrei bung/F eldbus kommuni kation/M ODBU S/Z ugriff auf R egister werte - Konfigurationsregister 0x2041, 0x2042, 0x2043 @ 8\mod_1278930636091_21.doc x @ 59643 @ @ 1
) with a word count of up to 65
dec
Description of the connected I/O modules
Read modules 65...128
Length 1...64 words
The node configuration can be specified in the 0x2031 register. The item number
of the I/O modules or fieldbus coupler/controller (without leading 750) is listed in
order. Because order numbers cannot be read out of digital modules, a code is
displayed for them, as defined below:
Bit position 0
Bit position 1
Bit position 2...7
Bit position 8...14
Bit position 15
) with a word count of up to 65
dec
Description of the connected I/O modules
Read modules 129...192
Length 1...64 words
The node configuration can be specified in the 0x2032 register. The item number
of the I/O modules or fieldbus coupler/controller (without leading 750) is listed in
order. Because order numbers cannot be read out of digital modules, a code is
displayed for them, as defined below:
Bit position 0
Bit position 1
Bit position 2...7
Bit position 8...14
Bit position 15
) with a word count of up to 65
dec
Description of the connected I/O modules
Read modules 193 ... 255
Length 1...63 words
The node configuration can be specified in the 0x2033 register. The item number
of the I/O modules or fieldbus coupler/controller (without leading 750) is listed in
order. Because order numbers cannot be read out of digital modules, a code is
displayed for them, as defined below:
Bit position 0
Bit position 1
Bit position 2...7
Bit position 8...14
Bit position 15
)
dec
Implement a software reset
Write (Write sequence 0xAA55 or 0x55AA)
The fieldbus coupler/controller performs a restart by writing the values 0xAA55 or
0x55AA.
Fieldbus Communication 181
Input module
Output module
Not used
Module size in bits
Designation digital module
Input module
Output module
Not used
Module size in bits
Designation digital module
Input module
Output module
Not used
Module size in bits
Designation digital module
Manual
Version 1.3.0