Canon imageRUNNER ADVANCE C2030 Service Manual page 693

Hide thumbs Also See for imageRUNNER ADVANCE C2030:
Table of Contents

Advertisement

COPIER > OPTION > CUSTOM
ATR12-SW
ON/OFF of ppr intvl ATVC ctrl: 1/2 speed
Lv.2 Details
To set whether to execute the ATR control between papers at 1/2
speed.
When the density variation is not within the requested range at
continuous output of a large volume of papers (long job length) with
1/2 speed (heavy paper, coated paper, etc.), set 1.
Both at 1/1 speed and 1/2 speed, specify the execution timing of
paper interval ATR control in INTROT-1.
Use case
When the density variation is not within the requested range at
continuous output of a large volume of papers with 1/2 speed
Adj/set/operate method Enter the setting value, and then press OK key.
Display/adj/set range
0 to 1
0: OFF, 1: ON
Default value
0
Related service mode
COPIER> OPTION> FNC-SW> INTROT-1
8
Service Mode > COPIER > OPTION > USER
T-8-51
8
Service Mode > COPIER > OPTION > USER
■ USER
COPIER > OPTION > USER
COPY-LIM
Setting of upper limit for copy
Lv.1 Details
To set the upper limit value for copy.
Use case
Upon user's request
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
1 to 9999
Default value
999
SLEEP
Setting of auto sleep function
Lv.1 Details
To set ON/OFF of auto sleep function.
Use case
Upon user's request
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
0 to 1
0: OFF, 1: ON
Default value
1
Supplement/memo
Transfer time to sleep mode is set in the user mode (Preferences>
Timer/Energy Settings> Auto Sleep Time).
SIZE-DET
ON/OFF of original size detect function
Lv.2 Details
To set ON/OFF of original size detection function.
Use case
Upon user's request (glare of the scan lamp, etc)
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
0 to 1
0: OFF, 1: ON
Default value
1
COUNTER1
Display of software counter 1
Lv.1 Details
To display counter type for software counter 1 on the Counter Check
screen.
Use case
Upon user/dealer's request
Adj/set/operate method Display only
Caution
Display only. No change is available.
Display/adj/set range
0 to 999
0: Not registered
Default value
The value differs according to the location.
COUNTER2
Setting of software counter 2
Lv.1 Details
To set counter type for software counter 2 on the Counter Check
screen.
Use case
Upon user/dealer's request
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
0 to 999
0: Not registered
Default value
The value differs according to the location.