Process/Operation > Embedded RDS > E-RDS Setup > Steps to E-RDS settings
6. Touch the numeric button [1] on the control panel (the setting value is changed to 1) and
touch the [OK] button. (The data is reflected to the setting value field.)
NOTE:
This operation enables the communication function with UGW.
CAUTION:
The following settings i.e. RGW-PORT and RGW-ADR in Service mode must not be
change unless there are specific instructions to do so.
Changing these values will cause error in communication with UGW.
2
Process/Operation > Embedded RDS > E-RDS Setup > Steps to E-RDS settings
7. Select [COM-TEST] and then touch [OK].
NOTE:
This initiates the communication test between the device and the UGW.
F-2-296
If the communication is successful, "OK!" is displayed. If "NG!" (failed) appears, refer to the
"Troubleshooting" and repeat until "OK!" is displayed.
NOTE:
The communication results with UGW can be distinguished by referring to the COM-
LOG. By performing the communication test with UGW, E-RDS acquires schedule
information and starts monitoring and meter reads operation.
2-179
F-2-297
F-2-298
2-179