E
Detail
Location
Item
Code
Code
E614 0007 00
Title
Error in file system on the Flash PCB
Description The ICC Profile is not found on the Flash PCB.
Remedy
1. Turn OFF the main power and check connection of the Flash
PCB, and then turn ON the main power.
2. Erase all partitions that can be initialized (all of erasable
partition data is erased)
Perform the procedure to enter service mode, Select the
following to enter 0: [1]:CHK-TYPE = 0, and execute the
following: [3]:HD-CLEAR = 1, and then turn OFF and ON the
power.
3. Start in safe mode and format the Flash PCB, and then
reinstall the system using SST or USB.
4. Replace the Flash PCB and reinstall the system using SST
or USB
5. Replace Main Controller PCB 1
E614 0008 00
Title
Error in file system on the Flash PCB
Description Thai font is not found on the Flash PCB.
Remedy
1. Turn OFF the main power and check connection of the Flash
PCB, and then turn ON the main power.
2. Erase all partitions that can be initialized (all of erasable
partition data is erased)
Perform the procedure to enter service mode, Select the
following to enter 0: [1]:CHK-TYPE = 0, and execute the
following: [3]:HD-CLEAR = 1, and then turn OFF and ON the
power.
3. Start in safe mode and format the Flash PCB, and then
reinstall the system using SST or USB.
4. Replace the Flash PCB and reinstall the system using SST
or USB
5. Replace Main Controller PCB 1
E614 0009 00
Title
Error in file system on the Flash PCB
Description The font for Print Report is not found on the Flash PCB.
Remedy
1. Turn OFF the main power and check connection of the Flash
PCB, and then turn ON the main power.
2. Erase all partitions that can be initialized (all of erasable
partition data is erased)
Perform the procedure to enter service mode, Select the
following to enter 0: [1]:CHK-TYPE = 0, and execute the
following: [3]:HD-CLEAR = 1, and then turn OFF and ON the
power.
3. Start in safe mode and format the Flash PCB, and then
reinstall the system using SST or USB.
4. Replace the Flash PCB and reinstall the system using SST
or USB
5. Replace Main Controller PCB 1
7
Error Code > Error Code > Error Code Details
Description
7
Error Code > Error Code > Error Code Details
E
Detail
Location
Item
Code
Code
E614 0010 00
Title
Error in file system on the Flash PCB
Description Simplified Chinese, Hangul, and traditional Chinese fonts are
not found on the Flash PCB.
Remedy
1. Turn OFF the main power and check connection of the Flash
PCB, and then turn ON the main power.
2. Erase all partitions that can be initialized (all of erasable
partition data is erased)
Perform the procedure to enter service mode, Select the
following to enter 0: [1]:CHK-TYPE = 0, and execute the
following: [3]:HD-CLEAR = 1, and then turn OFF and ON the
power.
3. Start in safe mode and format the Flash PCB, and then
reinstall the system using SST or USB.
4. Replace the Flash PCB and reinstall the system using SST
or USB
5. Replace Main Controller PCB 1
E614 0011 00
Title
Error in file system on the Flash PCB
Description Simplified Chinese, Hangul, and traditional Chinese fonts are
not found on the Flash PCB.
Remedy
1. Turn OFF the main power and check connection of the Flash
PCB, and then turn ON the main power.
2. Erase all partitions that can be initialized (all of erasable
partition data is erased)
Perform the procedure to enter service mode, Select the
following to enter 0: [1]:CHK-TYPE = 0, and execute the
following: [3]:HD-CLEAR = 1, and then turn OFF and ON the
power.
3. Start in safe mode and format the Flash PCB, and then
reinstall the system using SST or USB.
4. Replace the Flash PCB and reinstall the system using SST
or USB
5. Replace Main Controller PCB 1
E614 0012 00
Title
Error in file system on the Flash PCB
Description The web browser archive is not found on the Flash PCB.
Remedy
1. Turn OFF the main power and check connection of the Flash
PCB, and then turn ON the main power.
2. Erase all partitions that can be initialized (all of erasable
partition data is erased)
Perform the procedure to enter service mode, Select the
following to enter 0: [1]:CHK-TYPE = 0, and execute the
following: [3]:HD-CLEAR = 1, and then turn OFF and ON the
power.
3. Start in safe mode and format the Flash PCB, and then
reinstall the system using SST or USB.
4. Replace the Flash PCB and reinstall the system using SST
or USB
5. Replace Main Controller PCB 1
7-53