E
Detail
Location
Item
Code
Code
E067 0002 05
Title
Error in C primary transfer abnormal detection
Description When trying to apply the specified voltage of 1500 [V] or higher
* It occurs only in the case of Cont v28.30/Dcon v54.02 or
earlier.
Remedy
Error in the Primary Transfer High Voltage PCB, Error in the
Primary Transfer Roller (ITB Unit)
1. Check failure of the harness between the Primary Transfer
High Voltage PCB (UN04/J1001) and the DC Controller
PCB (UN09/J205) (open circuit, trapped cable, connector
disconnection).
-> Replace the harness if it is faulty
2. Check connection failure between the Primary Transfer High
Voltage PCB (UN04/J21) and the Primary Transfer Roller (Check
that the connection is free from open circuit or GND contact)
3. Replace the Primary Transfer High Voltage PCB (UN04)
4. Replace the ITB Unit
5. Replace the DC Controller PCB (UN09).
6. Replace the Primary Transfer Power Supply Unit
E067 0003 05
Title
Error in Bk primary transfer abnormal detection
Description When trying to apply the specified voltage of 1500 [V] or higher
* It occurs only in the case of Cont v28.30/Dcon v54.02 or
earlier.
Remedy
Error in the Primary Transfer High Voltage PCB, Error in the
Primary Transfer Roller (ITB Unit)
1.Check failure of the harness between the Primary Transfer
High Voltage PCB (UN04/J1001) and the DC Controller
PCB (UN09/J205) (open circuit, trapped cable, connector
disconnection).
-> Replace the harness if it is faulty
2. Check connection failure between the Primary Transfer High
Voltage PCB (UN04/J11) and the Primary Transfer Roller (Check
that the connection is free from open circuit or GND contact)
3. Replace the Primary Transfer High Voltage PCB (UN04)
4. Replace the ITB Unit
5. Replace the DC Controller PCB (UN09)
6. Replace the Primary Transfer Power Supply Unit
7
Error Code > Error Code > Error Code Details
Description
7
Error Code > Error Code > Error Code Details
E
Detail
Location
Item
Code
Code
E069 0001 05
Title
Abnormal current is detected at the secondary transfer
Description When 5 [uA] or smaller is detected at the secondary transfer
Remedy
Error in the Secondary Transfer High Voltage PCB, Error in the
Secondary Transfer Roller
1. Check failure of the harness between the Secondary
Transfer High Voltage PCB (UN05/J201) and the DC Controller
PCB (UN09/J10) (open circuit, trapped cable, connector
disconnection).
-> Replace the harness if it is faulty
2.Check connection failure between the Secondary Transfer
High Voltage PCB (UN05/T1201) and the Secondary Transfer
Outer Roller (Check that the connection is free from open circuit
or GND contact)
3. Replace the Secondary Transfer High Voltage PCB (UN05)
4. Replace the Secondary Transfer Outer Roller
5. Replace the ITB Unit
6. Replace the DC Controller PCB (UN09)
7. Replace the Secondary Transfer Power Supply Unit
E074 0000 05
Title
Error in the primary transfer disengagement control
Description At the primary transfer disengagement control, the sensor fails
to detect although the specified time has passed (the specified
time differs depending on the mode)
Remedy
Error in the Primary Transfer Disengagement Solenoid, Error in
the Primary Transfer Disengagement Switch, or the ITB Guide
Rail error
1. Replace the ITB Unit
2. Check the harness/connector between the DC Controller
PCB (UN09/J11) and the Primary Transfer Disengagement
Switch (SW01)
3. Check the harness/connector between the DC Controller
PCB (UN09/J11) and the Primary Transfer Disengagement
Solenoid (SL01)
4. Check conduction of FU6 on the DC Controller PCB (UN09)
5. Replace the ITB Guide Rail
6. Replace the Main Drive
7. Replace the Fixing Drive
8. Replace the DC Controller PCB (UN09)
7-28