E040 0002 05
Title
Cassette 1 Lifter error
Description Unable to detect the lift-up completion position within 4.5 sec
after lift-up was started
Remedy
Error in Lift Motor or Lifter Sensor
1. While Cassette 1 is removed, turn ON the power and then
insert Cassette 1.
When there is operation sound of the motor
1-1. Check the harness/connector between the DC Controller
(UN09/J13) and the Cassette 1 Lifter Sensor (PS12)
2-1. Check if the Cassette 1 Lifter Sensor (PS12) is installed.
3-1. Check the condition of the gear at the host machine side (to
see if there is missing or swing with the gear)
4-1. Replace the Cassette 1 Lifter Sensor (PS12)
5-1. Replace the DC Controller PCB (UN09)
When there is no operation sound of the motor
1-2. Check the harness/connector between the DC Controller
(UN09/J13) and the Cassette 1 Lifter Motor (M14)
2-2. Check conduction of the fuse (FU2) of the DC Controller
(UN09)
3-2. Check the condition of the gear at the host machine side (to
see if there is something missing or swing with the gear)
4-2. Check the Cassette 1 Lifter Motor (M14)
5-2. Replace the DC Controller (UN09)
E065 0000 05
Title
Error in detection of abnormal Y charging AC current value
Description During the paper interval simple discharge current control, a
current value that is higher than the target of 500[uA] is detected
Remedy
Error in output of charging high voltage, Drum Unit error or
environment control error
1. COPIER > DISPLAY > ANALOG; check if the TEMP
value and the HUM value are matched with the environment
temperature.
When the values are dramatically mismatched (Lager than
15degrees Celsius)
2-1. Check the harness and connector between the DC
Controller (UN09/ J206) and the Environment Sensor (UN45)
3-1. Replace the Environment Sensor (UN45)
4-1. Replace the DC Controller (UN09)
When the values are matched
2-2. Check the state of the charging high voltage contact point
3-2. Replace the Drum Unit (Y)
4-2. Check the harness and connector between the DC
Controller PCB (UN09/ J21) and the Primary Charging High
Voltage PCB (UN06/ J441, J442)
5-2. Replace the Primary Charging High Voltage PCB (UN06)
6-2. Replace the DC Controller PCB (UN09)
7
Error Code > Error Code > Error Code Details
Description
7
Error Code > Error Code > Error Code Details
E
Detail
Location
Item
Code
Code
E065 0001 05
Title
Error in detection of abnormal M charging AC current value
Description During the paper interval simple discharge current control, a
current value that is higher than the target of 500[uA] is detected
Remedy
Error in output of charging high voltage, Drum Unit error or
environment control error
1. COPIER > DISPLAY > ANALOG; check if the TEMP
value and the HUM value are matched with the environment
temperature.
When the values are dramatically mismatched (Lager than
15degrees Celsius)
2-1. Check the harness and connector between the DC
Controller (UN09/ J206) and the Environment Sensor (UN45)
3-1. Replace the Environment Sensor (UN45)
4-1. Replace the DC Controller (UN9)
When the values are matched
2-2. Check the state of the charging high voltage contact point
3-2. Replace the Drum Unit (M)
4-2. Check the harness and connector between the DC
Controller PCB (UN09/ J21) and the Primary Charging High
Voltage PCB (UN06/ J441, J442)
5-2. Replace the Primary Charging High Voltage PCB (UN06)
6-2. Replace the DC Controller PCB (UN09)
E065 0002 05
Title
Error in detection of abnormal C charging AC current value
Description During the paper interval simple discharge current control, a
current value that is higher than the target of 500[uA] is detected
Remedy
Error in output of charging high voltage, Drum Unit error or
environment control error
1. COPIER > DISPLAY > ANALOG; check if the TEMP
value and the HUM value are matched with the environment
temperature.
When the values are dramatically mismatched (Lager than
15degrees Celsius)
2-1. Check the harness and connector between the DC
Controller (UN09/ J206) and the Environment Sensor (UN45)
3-1. Replace the Environment Sensor (UN45)
4-1. Replace the DC Controller (UN9)
When the values are matched
2-2. Check the state of the charging high voltage contact point
3-2. Replace the Drum Unit (C)
4-2. Check the harness and connector between the DC
Controller PCB (UN09/ J21) and the Primary Charging High
Voltage PCB (UN06/ J441, J442)
5-2. Replace the Primary Charging High Voltage PCB (UN06)
6-2. Replace the DC Controller PCB (UN09)