COPIER > FUNCTION > INSTALL
AINR-OFF
ON/OFF warm-up rotn deact:dor open/close
Lv.1 Details
To set whether to disable the warm-up rotation when opening and
closing the door.
By selecting 1, printing can be executed without auto adjustment at
warm-up rotation when analyzing the cause of a problem.
Use case
When printing and checking without auto adjustment at warm-up
rotation when analyzing the cause of a problem
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
0 to 1
0: OFF (warm-up rotation enabled), 1: ON (warm-up rotation
disabled)
Default value
0
E-RDS
Set use/no use of Embedded-RDS function
Lv.1 Details
To set whether to use the Embedded-RDS function.
Use case
When using Embedded-RDS
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Caution
Be sure to use E-RDS, RGW-PORT, COM-TEST, COM-LOG and
RGW-ADR as a set.
Display/adj/set range
0 to 1
0: Function not used, 1: Function used (All the counter information is
sent.)
Default value
0
Related service mode
COPIER> FUNCTION> INSTALL> RGW-PORT, COM-TEST, COM-
LOG, RGW-ADR
Supplement/memo
Embedded-RDS: Function to send device information such as the
device counter, failure, and consumables etc. to the sales company's
server via SOAP protocol
RGW-PORT
Set port number of Sales Co's server
Lv.1 Details
To set the port number of the sales company's server to be used for
Embedded-RDS.
Use case
When using Embedded-RDS
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Caution
Be sure to use E-RDS, RGW-PORT, COM-TEST, COM-LOG and
RGW-ADR as a set.
Display/adj/set range
1 to 65535
Default value
443
Related service mode
COPIER> FUNCTION> INSTALL> E-RDS, COM-TEST, COM-LOG,
RGW-ADR
Supplement/memo
Embedded-RDS: Function to send device information such as the
device counter, failure, and consumables etc. to the sales company's
server via SOAP protocol
8
Service Mode > COPIER > FUNCTION > INSTALL
8
Service Mode > COPIER > FUNCTION > INSTALL
COPIER > FUNCTION > INSTALL
COM-TEST
Dis connect result w/ Sales Co's server
Lv.1 Details
To display the result of the connection test with the sales company's
server.
Use case
When using Embedded-RDS
Adj/set/operate method Select the item, and then press OK key.
Caution
Be sure to use E-RDS, RGW-PORT, COM-TEST, COM-LOG and
RGW-ADR as a set.
Display/adj/set range
During operation: ACTIVE, When connection is completed: OK,
When connection is failed: NG
Related service mode
COPIER> FUNCTION> INSTALL> E-RDS, RGW-PORT, COM-LOG,
RGW-ADR
Supplement/memo
Embedded-RDS: Function to send device information such as the
device counter, failure, and consumables etc. to the sales company's
server via SOAP protocol
COM-LOG
Dis connect error w/ Sales Co's server
Lv.1 Details
To display error information when the connection with the sales
company's server failed.
Use case
When using Embedded-RDS
Adj/set/operate method Display only
Caution
Be sure to use E-RDS, RGW-PORT, COM-TEST, COM-LOG and
RGW-ADR as a set.
Display/adj/set range
Year, date, time, error code, error detail information (maximum 128
characters)
Related service mode
COPIER> FUNCTION> INSTALL> E-RDS, RGW-PORT, COM-TEST,
RGW-ADR
Supplement/memo
Embedded-RDS: Function to send device information such as the
device counter, failure, and consumables etc. to the sales company's
server via SOAP protocol
RGW-ADR
URL setting of Sales Company's server
Lv.1 Details
To set the URL of the sales company's server to be used for
Embedded-RDS.
Use case
When using Embedded-RDS
Adj/set/operate method 1) Select the URL.
2) Enter the URL, and then press OK key.
3) Turn OFF/ON the main power switch.
Caution
- Do not use Shift-JIS character strings.
- Be sure to use E-RDS, RGW-PORT, COM-TEST, COM-LOG and
RGW-ADR as a set.
Display/adj/set range
URL
Default value
https://a01.ugwdevice.net/ugw/agentif010
Related service mode
COPIER> FUNCTION> INSTALL> E-RDS, RGW-PORT, COM-TEST,
COM-LOG
Supplement/memo
Embedded-RDS: Function to send device information such as the
device counter, failure, and consumables etc. to the sales company's
server via SOAP protocol