<When an error is detected by diagnosis>
Detailed information is displayed under the judgment result. In detailed information, the name
of the test where an error was detected is indicated.
<How to view the error result>
The following screen is an enlarged view of the detailed information indicated above.
Explanation of the detailed error information is described.
[no] means that optional PCBs are not mounted.
When [no] is displayed although an optional PCB is mounted, it means that an error has been
occurring.
[NG] means that an error occurred to PCBs mounted as standard.
NOTE:
Once the tool is activated, this machine reboots after approx. 2 minutes.
After completion of the diagnosis, be sure to turn OFF and then ON the main power.
By turning the power OFF, the operation of this tool completes.
6
Troubleshooting > Controller Self Diagnosis > Operation > Controller System Error Diagnosis
F-6-151
F-6-152
6
Troubleshooting > Controller Self Diagnosis > Operation > Controller System Error Diagnosis
<Controller System Error Diagnosis Table>
The error locations are identified according to the following table.
Test
Description
Assumed Error
Name
Location
SN-1 IA-
Check an error
Main Controller
DDR2
between the
PCB 1
SDRAM
Main Controller
SDRAM on Main
PCB 1 and
Controller PCB 1
SDRAM on the
Main Controller
PCB 1
SN-2 SM
Check an
Main Controller
BUS IA
SM bus error
PCB 1
DIMM1
in SDRAM
SDRAM (outside)
(outside) on the
on Main Controller
Main Controller
PCB 1
PCB 1
SN-3 SM
Check an SM
Main Controller
BUS IA
bus error in
PCB 1
DIMM2
SDRAM (inside)
SDRAM (inside)
on the Main
on Main Controller
Controller PCB 1
PCB 1
SN-4 SM
Check an SM
Main Controller
BUS IA
bus error in
PCB 1
Clock Gen
Clock Generator
on the Main
Controller PCB 1
SN-5 SM
Check an SM
Main Controller
BUS SOC
bus error in the
PCB 1
DIMM1
Main Controller
PCI Expansion
PCB 1 and
PCB
SDRAM on the
Main Controller
Main Controller
PCB 2
PCB 2
DDR2 SDRAM on
Main Controller
PCB 2
SN-6 PCI
Test a PCI bus
PCI bus error
Config
between the
between Main
SOC
Main Controller
Controller PCB
PCB 1 and the
1 and Main
Main Controller
Controller PCB 2
PCB 2
SN-7 PCI
Check a LAN
Main Controller
Config
chip error on the
PCB 1
LANC
Main Controller
PCB 1
6-115
Remedy
Error
Code
1. Check the installation of SDRAM on
-
the Main Controller PCB.
2. Replace SDRAM on the Main
Controller PCB 1.
3. Replace the Main Controller PCB 1.
1. Check the installation of SDRAM on
-
the Main Controller PCB.
2. Replace SDRAM (outside) of the Main
Controller PCB 1.
3. Replace the Main Controller PCB 1.
1. Check the installation of SDRAM on
-
the Main Controller PCB 1.
2. Replace SDRAM (inside) of the Main
Controller PCB 1.
3. Replace the Main Controller PCB 1.
1. Replace the Main Controller PCB 1.
-
1. Check the connection of the Main
-
Controller PCB 1, and the Main
Controller PCB 2.
2. Check the installation of DDR2 SDRAM
on the Main Controller PCB 2.
3. Replace DDR2 SDRAM on the Main
Controller PCB 2.
4. Replace the Main Controller PCB 2.
5. Replace the Main Controller PCB 1.
1. Check the connection of the Main
-
Controller PCB 1, and ascertain
presence of breach.
2. Replace the Main Controller PCB 1.
1. Replace the Main Controller PCB 1.
-
6-115