K&R GT600-4T132G User Manual page 94

Ac drive high performance open and closed loop
Table of Contents

Advertisement

5. Quick Setup
CONTINUE
5
Para.
Parameter name
F4-00
DI1 function selection
33: External fault normally closed (NC) input
34: Frequency modification forbidden
35: PID action direction reverse
36: External STOP terminal 1
37: Command source switchover terminal 2
38: PID integral disabled
39: Switchover between main frequency source X and
preset frequency
40: Switchover between auxiliary frequency source Y and
preset frequency
41: Motor selection terminal 1
42: Motor selection terminal 2
43: PID parameter switchover
44: User-defined fault 1
45: User-defined fault 2
46: Speed control/Torque control switchover
47: Emergency stop
48: External STOP terminal 2
49: Deceleration DC injection braking
50: Clear the current running time 51–
59: Reserved
Setting range:0 to 59;
F4-01
DI2 function selection
Setting range same as DI1.
F4-02
DI3 function selection
Setting range same as DI1.
F4-03
DI4 function selection
Setting range same as DI1.
F4-04
DI5 function selection
Setting range same as DI1;
F4-05
DI6 function selection
Setting range same as DI1;
F4-06
DI7 function selection
Setting range same as DI1;
F4-07
DI8 function selection
Setting range same as DI1
F4-08
DI9 function selection
Setting range same as DI1.
F4-09
DI10 function selection
Setting range same as DI1;
Para.
Parameter name
Default
Commission
1
4
9
12
13
0
0
0
0
0
Default
Commission
- 93 -