Value
Function
49
Deceleration DC
injection braking
50
Clear running time
this time
51
Two-wire control/
Three-wire control
52
Reverse running
prohibited
53 to 59 Reserved
Function Code
Parameter Name
F4-35
DI1 delay
F4-36
DI2 delay
F4-37
DI3 delay
When state of DI terminals changes, these three function parameters set delay time of the
change. Now the drive supports delay function on DI1, DI2 and DI3 only.
Function Code
Parameter Name
F4-38
DI active mode
selection 1
F4-39
DI active mode
selection 2
These two function parameters set active mode of DI terminals.
0: High level active
If a high level voltage is applied to DI terminal, the DI signal will be seen as active. That is,
the DI terminal becomes active when being connected with COM, and inactive when being
disconnected from COM.
1: Low level active
If a low level voltage is applied to DI terminal, the DI signal will be seen as active. That is, the
DI terminal becomes active when being disconnected from COM, and inactive when being
connected with COM.
Description
When terminal set for this function becomes on, the AC drive
decelerates to DC injection braking 2 frequency threshold and
then switches over to DC injection braking state.
When terminal set for this function becomes on, current running
time of the AC drive is cleared. This function must be supported
by F8-42 and F8-53.
This function enables the AC drive to switch over between two-
wire control and three-wire control. If F4-11 is set to two-wire
control mode 1, the AC drive switches over to three-wire control
mode 1 when terminal set for this function becomes on.
When terminal set for this function becomes on, reverse running
of the AC drive is prohibited. It is the same as function of F8-13.
-
Setting Range
0.0s to 3600.0s
0.0s to 3600.0s
0.0s to 3600.0s
Setting Range
0: High level active
1: Low level active
Units position: DI1 active mode
Tens position: DI2 active mode
Hundreds position: DI3 active mode
Thousand position: DI4 active mode
Ten thousands position: DI5 active mode
0: High level active
1: Low level active
Units position: DI6 active mode
Tens position: DI7 active mode
Hundreds position: DI8 active mode
Thousands position: DI9 active mode
Ten thousands position: DI10 active mode
6. Description of Parameters
Default
0.0s
0.0s
0.0s
Default
00000
00000
6