Value Function
12
Multi-reference terminal 1
13
Multi-reference terminal 2
14
Multi-reference terminal 3
15
Multi-reference terminal 4
16
Terminal 1 for
acceleration/deceleration
time selection
17
Terminal 2 for
acceleration/deceleration
time selection
18
Frequency reference
setting channel
switchover
19
UP and DOWN setting
clear (terminal, operation
panel)
20
Command source
switchover 1
21
Acceleration/Deceleration
prohibited
22
PID disabled
23
PLC state reset
24
Wobble disabled
25
Counter input
26
Counter reset
27
Length signal pulses
count
28
Length reset
29
Torque control prohibited
30
Pulse input as frequency
reference (valid only for
DI5)
31
Reserved
32
Immediate DC injection
braking
Description
16 speeds or 16 other references can be implemented
through combinations of 16 states of these four terminals.
Totally four groups of acceleration/deceleration time can be
selected through combinations of four states of these two
terminals.
The terminal set for this function is used to perform
switchover between two frequency reference setting channels
according to setting in F0-07.
If the frequency source is digital setting, the terminal set for
this function is used to clear the modification by using the
UP/DOWN function or the increment/decrement key on the
operation panel, restoring the frequency reference to the
value of F0-08.
If command source is terminal control (F0-02 = 1), this
terminal is used to perform switchover between terminal
control and operation panel control.
If command source is communication control (F0-02 =
2), this terminal is used to perform switchover between
communication control and operation panel control.
This function ensures the AC drive to maintain current
frequency output without being affected by external signals
(except STOP command).
This function disables the PID function. The AC drive
maintains current frequency output without supporting PID
adjustment of frequency reference.
When the simple PLC function is enabled again after it was
disabled in execution process, this function restores original
state of simple PLC for the AC drive
When terminal set for this function becomes on, the wobble
function becomes disabled and the drive outputs center
frequency.
Terminal set for this function is used to count pulses.
Terminal set for this function is used to clear counter.
Terminal set for this function is used to count pulses of the
length signal.
The terminal set for this function is used to clear length.
When the terminal set for this function becomes on, torque
control is disabled and the AC drive enters speed control.
DI5 is used for pulse input as frequency reference.
-
Once the terminal set for this function becomes on, the AC
drive directly switches over to DC injection braking state.