6. Description of Parameters
Function Code
U0-44
U0-44: It displays whether DI terminals set for functions 41 to 59 are active. The display format is
similar to U0-43. The 7-segment LEDs display functions 41–48, 49–56 and 57–59, respectively
from right to left.
Function Code
U0-58
U0-58: It displays phase Z counting of current ABZ or UVW encoder. The value increases or
decreases by 1 every time encoder rotates one revolution forwardly or reversely. You can check
whether installation of encoder is normal by viewing U0-58.
Function Code
U0-59
U0-60
Function Code
U0-61
U0-61: It displays the drive state. The data format is listed in the following table:
Bit0
Bit1
Bi2
Bit3
Bit4
Function Code
U0-62
U0-63
U0-64
U0-65
U0-74
U0-76
U0-77
U0-78
Parameter Name
DI set for function state display 2
Parameter Name
Phase Z counting
Parameter Name
Frequency Reference
Running frequency
Parameter Name
AC drive state
0: Stop
1: Forward
2: Reverse
0: Constant
1: Accelerate
2: Decelerate
0: Bus voltage normal
1: Undervoltage
Parameter Name
Current fault code
Sending value of point-point
communication
Number of slaves
Torque upper limit
AC drive output torque
Low bits of accumulative power
consumption
High bits of accumulative power
consumption
Linear speed
Display Range
-
Display Range
0 to 65535
Display Range
-100.00% to 100.00%
-100.00% to 100.00%
Display Range
0 to 65535
Display Range
0 to 99
-100.00% to 100.00%
0 to 63
-200.00% to 200.00%
-200.0% to 200.00%
0.0 to 999.0 (min. unit: 0.1° )
0 to 65535 (min. unit: 1° )
0 to 65535
6
- 171 -

Advertisement

Table of Contents
loading

Table of Contents