6. Description of Parameters
6
- 136 -
F6-00 = 0: Direct Start
It is applicable to most small-inertia loads, as shown in Figure 6-30 (1).
Start frequency is applicable to drive equipment which requires startup torque, such as
cement mixer, as shown in Figure 6-30 (2).
The DC injection braking function is applicable to drive load such as elevator and crane,
as shown in Figure 6-30 (3).
Figure 6-30 (1) Sequence of direct start
Output frequency
RUN command
Figure 6-30 (2) Sequence of start with start frequency
Output frequency
RUN command
F6-04 Acceleration time
(Start frequency
holding time)
Figure 6-30 (3) Sequence of start with DC injection braking
Output frequency
RUN command
DC injection
braking active
F6-06
(DC injection braking 1
active time)
Acceleration time
F6-03
(start frequency)
Acceleration time