Para. No.
Para. Name
F9-62
Threshold of power dip ride-
through function enabled
F9-63
Load lost protection
F9-64
Load lost detection level
F9-65
Load lost detection time
F9-67
Overspeed detection level
F9-68
Overspeed detection time
F9-69
Detection level of speed error
F9-70
Detection time of speed error
F9-71
Power dip ride-through gain Kp
F9-72
Power dip ride-through integral
coefficient
F9-73
Deceleration time of power dip
ride-through
Group FA: PID Function
FA-00
PID reference setting channel
FA-01
PID digital setting
FA-02
PID feedback setting channel
FA-03
PID operation direction
FA-04
PID reference and feedback range 0 to 65535
FA-05
Proportional gain Kp1
FA-06
Integral time Ti1
FA-07
Differential time Td1
FA-08
PID output limit in reverse
direction
FA-09
PID error limit
FA-10
PID differential limit
FA-11
PID reference change time
FA-12
PID feedback filter time
FA-13
PID output filter time
FA-14
Reserved
FA-15
Proportional gain Kp2
FA-16
Integral time Ti2
FA-17
Differential time Td2
FA-18
PID parameter switchover
condition
FA-19
PID error 1 for auto switchover
Setting Range
60% to 100%
0: Disabled
1: Enabled
0.0% to 100.0%
0.0s to 60.0s
0.0% to 50.0% (max.
frequency)
0.0s to 60.0s
0.0% to 50.0% (max.
frequency)
0.0s to 60.0s
0 to 100
0 to 100
0.0s to 300.0s
0 to 6
0.0% to 100.0%
0 to 8
0, 1
0.0 to 1000.0
0.01s to 10.00s
0.000s to 10.000s
0.00 Hz to max. frequency
0.0% to 100.0%
0.00% to 100.00%
0.00s to 650.00s
0.00s to 60.00s
0.00s to 60.00s
-
0.0 to 1000.0
0.01s to 10.00s
0.000s to 10.000s
0 to 3
0.0% to FA-20
Appendix B Parameter Table
Default
Property Page
80%
0
10.0%
1.0s
20.0%
1.0s
20.0%
5.0s
40
30
20.0s
0
50.0%
0
0
1000
20.0
2.00s
0.000s
0.00 Hz
0.0%
0.10%
0.00s
0.00s
0.00s
-
-
-
20.0
2.00s
0.000s
0
20.0%

Advertisement