Type
Terminal
Digital
DO1
CME
outputs
FM
COM
Relay
T/A
T/B
outputs
T/A
T/C
Auxiliary
J13
interfaces
J4
J11
Jumpers
J7
<2>
J9
J10
<1>
: Select 500 Ω or 250 Ω input impedance according to with-load capacity
Note
of signal source. For example, if 500 Ω is selected, maximum output
voltage of signal source must not be smaller than 10 V so that AI2 can
measure 20 mA current.
<2>
: For positions of jumpers J7, J9 and J10, refer to
Name
Description
Digital output 1
Optically-coupled isolation, dual-polarity
open-collector output
Output voltage range: 0 to 24 V
Output current range: 0 to 50 mA.
Note that CME and COM are internally
insulated, but are shorted externally by a
jumper. In this case, DO1 is driven by +24
V by default. Remove the jumper link if
you need to apply external power to DO1.
High-speed pulse
Controlled by F5-00 (FM terminal output
output
selection).
Max. output frequency: 100 kHz.
When used as an open-collector output,
the specification is the same as for DO1.
Normally-closed
Contact driving capacity:
(NC) terminal
250 VAC, 3 A, Cos f = 0.4
Normally-open
30 VDC, 1 A
(NO) terminal
Applies to overvoltage Category II circuit
Extension card
Interface for the 28-core terminal and
interface
optional cards
(I/O extension card, PLC card and various
bus cards)
PG card interface
Open-collector, UVW and Resolver are
selectable options.
External
Connected to an external operating panel.
operating panel
interface
AO1 output
Either a voltage or a current output,
selection
voltage output by default
AI2 input
Either a voltage or a current input, voltage
selection
input by default.
Either 500 Ω or 250 Ω input, 500 Ω input
AI2 input
impedance
by default
selection
.