4. Operating Panel (Keypad & Display)
Press
1. Save the parameter value you have set
2. Return to Level II menu, and then
3. Select the next function parameter.
Press
1. Return to Level II menu without saving the parameter value, and remain at the current
4
- 78 -
from a Level III menu to:
ENTER
from a Level III menu to:
PRG
function code.
Unmodifiable Parameters
When operating in Level III menus, if the parameter does not include a flashing digit, then
it is not possible to modify that parameter. There are two possible reasons for this:
1. The function parameter you have selected is read-only. This is because:
The display is showing the AC drive model.
The display is showing an actual parameter detected by the system.
The display is showing a running record parameter.
2. The displayed function parameter cannot be modified while the AC drive is in the
RUNNING status. You can modify these types of parameter only when the AC drive is
in the STOP status.