Wiring of AI1
Analog signals at low levels can suffer from effects of external interference. To reduce
this effect, it is important to use shielded cables shorter than 20 m long to carry analog
signals.
Figure 3-18 Wiring for analog input 1
In applications where analog signals suffer from effects of severe external interference,
install a filter capacitor or a ferrite magnetic core at source of analog signal. The pig tail of
the shield must be connected to the PE terminal on the drive.
Figure 3-19 Connect shield to the PE terminal of the drive
a
a
Ground
bar
Grounding clamp
■
Wiring of AI2
When you select voltage input via AI2, use the same wiring method as AI1. When you
select current input via AI2, set jumper J9 to the I side.
Figure 3-20 Wiring for analog input 2
< 20 m
Potentiometer
a
b
Current flow in
Ferrite magnetic core
Cross or wind two or three
turns in the same direction
3. Electrical Installation
GT600
+10V
AI1
GND
PE
Press it to open the
grounding clamp.
GT600
AI2
I
V
J9
GND
3