K&R GT600-4T132G User Manual page 177

Ac drive high performance open and closed loop
Table of Contents

Advertisement

Figure 6-51 Counting function
Any of F4-04
Allocate DIx with the
to F4-09 = 25 counter input function.
DIx
DIx
Any of F4-04
Allocate DIx with the
to F4-09 =26
counter reset function.
Count pulse input
1 2 3
Count reset input
Output of set count
value reached
Output of designated
count value reached
The settings of related function parameters in the preceding figure are as follows:
Function Code
Any of F4-00 to F4-09
Any of F4-00 to F4-09
Any of F5-00 to F5-05
Any of F5-00 to F5-05
Note
Fb-08
Set count value
Compare
U0-12
Count value
Clear to 0
Fb-09
Designated
count value
10 11 12
Fb-08 = 11
U0-12 = 11
Parameter Name
DIx function selection
DIx function selection
DOx function selection
DOx function selection
For high pulse frequency, use terminal DI5.
You cannot allocate "Set counting value reached" function and "Designated
counting value reached" function to the same DO terminal.
The counter keeps counting in the drive running/stop status. It stops counting
until the set counting value is reached.
The counting value is retentive at power down.
An automatic stop system can be implementing by connecting the output
counting value reached signal of DO to the stop input terminal.
6. Description of Parameters
Any of F5-00
Allocate DO with the set
to F5-05 = 8
count value reached function.
DO
Reset
DO
Reset
Any of F5-00
to F5-05 = 8
19 20 21
U0-12 = 0
Fb-09 = 20
U0-12 = 20
Setting
Description
25
Counter input
26
Counting reset
8
Set counting value reached
9
Designated counting value reached
DO outputs the set count
value reached signal.
DO outputs the
designated count
value reached signal.
Allocate DO with the
designated count value
reached function.
U0-12 (Count value)
1 2
6
- 175 -