K&R GT600-4T132G User Manual page 197

Ac drive high performance open and closed loop
Table of Contents

Advertisement

Value Function
10
Length reached
11
PLC cycle
completed
12
Accumulative
running time
reached
13
Frequency limited
14
Torque limited
15
Ready for RUN
16
AI1 > AI2
17
Frequency upper
limit reached
18
Frequency lower
limit reached (no
output at stop)
19
Undervoltage
20
Communication
setting
21
Reserved
22
Reserved
23
Zero-speed
running 2 (having
output at stop)
24
Accumulative
power-on time
reached
25
Frequency level
detection 2
26
Frequency 1
reached
27
Frequency 2
reached
28
Current 1 reached
29
Current 2 reached
30
Timing reached
31
AI1 input
exceeding limit
32
Load lost
Description
Terminal set for this function becomes on when detected actual
length exceeds value set in Fb-05.
Terminal set for this function outputs a pulse signal with width of 250
ms when simple PLC completes one cycle.
Terminal set for this function becomes on when accumulative
running time of the AC drive exceeds value set in F8-17.
Terminal set for this function becomes on when frequency reference
exceeds frequency upper or lower limit, and output frequency of the
AC drive also reaches the upper or lower limit.
Terminal set for this function becomes on when the AC drive enters
stall protection because output torque reaches toque limit in speed
control.
Terminal set for this function becomes on when the AC drive is ready
to drive motor (Power applied to main circuit and control circuit is
normal, and no fault is detected).
When AI1 input is greater than AI2 input, terminal set for this function
becomes on.
When running frequency reaches frequency upper limit, terminal set
for this function becomes on.
When running frequency reaches frequency lower limit, terminal set
for this function becomes on. When the AC drive is in stop status,
terminal set for this function becomes off.
Terminal set for this function becomes on when undervoltage occurs
on AC drive.
Whether terminal is active or inactive is determined by
communication address 0x2001.
-
-
When output frequency is 0 during drive running, terminal set for this
function becomes on. When the drive stops, terminal remains on.
Terminal set for this function becomes on when accumulative power-
on time of the AC drive (F7-13) exceeds value set in F8-16.
Refer to descriptions of
Refer to descriptions of
Refer to descriptions of
Refer to descriptions of
Refer to descriptions of
On the condition that the timing function is enabled (F8-42 = 1),
terminal set for this function becomes on when current running time
of the AC drive reaches the set time.
Terminal set for this function becomes on when AI1 input is larger
than value set in F8-46 (AI1 input voltage upper limit) or smaller than
value set in F8-45 (AI1 input voltage lower limit).
Terminal set for this function becomes on when load gets lost.
6. Description of Parameters
and
.
and
.
and
.
and
.
and
.
6
- 195 -