K&R GT600-4T132G User Manual page 339

Ac drive high performance open and closed loop
Table of Contents

Advertisement

Appendix B Parameter Table
Para. No.
Para. Name
F5-21
DO2 output delay
F5-22
DI active mode selection 1
Para. No.
Para. Name
Group F6: Start/Stop Control
F6-00
Start mode
F6-01
Mode of catching a spinning motor 0: From stop frequency
F6-02
Speed of catching a spinning
motor
F6-03
Start frequency
F6-04
Start frequency holding time
F6-05
DC injection braking 1 level/Pre-
excitation level
F6-06
DC injection braking 1 active time
/Pre-excitation active time
F6-07
Acceleration/Deceleration mode
F6-08
Time proportion of S-curve start
segment
F6-09
Time proportion of S-curve end
segment
F6-10
Stop mode
F6-11
DC injection braking 2 start
frequency
F6-12
DC injection braking 2 delay time
F6-13
DC injection braking 2 level
F6-14
DC injection braking 2 active time
F6-15
Braking use ratio
F6-18
Catching a spinning motor current
limit
F6-21
Demagnetization time (effective
for SVC)
Setting Range
0.0s to 3600.0s
00000 to 11111
Setting Range
0: Direct start
1: Catching a spinning motor
2: Pre-excited start
3: SVC quick start
1: From 50 Hz
2: From max. frequency
1 to 100
0.00 to 10.00 Hz
0.0s to 100.0s
0% to 100%
0.0s to 100.0s
0 to 2
0.0% to (100.0% – F6-09)
0.0% to (100.0% – F6-08)
0: Decelerate to stop
1: Coast to stop
0.00 Hz to maximum
frequency
0.0 to 100.0s
0% to 100%
0.0s to 100.0s
0% to 100%
30% to 200%
0.00s to 5.00s
Default
Property Page
0.0s
00000
Default
Property Page
0
0
20
0.00 Hz
0.0s
50%
0.0s
0
30.0%
30.0%
0
0.00 Hz
0.0s
50%
0.0s
100%
-
Model
-
dependent
Model
-
dependent
12
- 337 -

Advertisement

Table of Contents
loading