6. Description of Parameters
6
- 110 -
Digital Setting (Non-retentive at Power Down)
The initial value of frequency reference is F0-08 (Preset frequency). You can modify
frequency reference by pressing
DOWN function of input terminals).
When the AC drive is powered on again, frequency reference continues from the value of
F0-08.
Digital Setting (Retentive at Power Down)
The initial value of frequency reference is F0-08 (Preset frequency). You can change
frequency reference by pressing
DOWN function of input terminals).
When the AC drive is powered on again, frequency reference continues from where it last
reached.
Function Code
Parameter Name
F0-08
Preset frequency
F0-10
Max. frequency
F0-23 (Retentive selection of digital setting frequency upon stop) determines
Note
whether to save frequency reference selection by pressing
via the up/down function when the AC drive stops. It is not the same as F0-
03 = 0 or 1, which determines whether to retain the setting on power-off.
Function Code
Parameter Name
F0-23
Retentive selection of digital
setting frequency upon stop
F0-23 is valid only when frequency reference setting channel is digital setting.
F0-23 = 0: Non-retentive
The AC drive resumes frequency reference to the value set in F0-08 at stop.
Frequency reference continues from the value of F0-08 at next power-on.
F0-23 = 1: retentive
The AC drive retains the frequency reference that was last reached at stop. Frequency
reference continues from the retained value at next power-on.
For example, F0-08 is set to 40 Hz and you increase it to 45 Hz by pressing
drive resumes frequency reference to 40 Hz after stop. If F0-23 = 1,
F0-23 = 0, The
frequency reference remains at 45 Hz after stop.
and
on the operating panel (or using the UP/
and
on the operating panel (or using the UP/
Setting Range
0.00 to max. frequency (F0-10)
50.00 to 500.00 Hz
Setting Range
0: Not retentive
1: Retentive
Default
50.00 Hz
50.00 Hz
and
or
Default
50.00 Hz
. If

Advertisement

Table of Contents
loading

Table of Contents