K&R GT600-4T132G User Manual page 261

Ac drive high performance open and closed loop
Table of Contents

Advertisement

DIP switch setting
Table 8-11 Descriptions of DIP switch setting
Baud Rate Definition Address setting
1
2
0
0
125Kbps
0
1
250Kbps
1
0
500Kbps
1
1
1Mbps
Indicators
Table 8-12 Descriptions of indicators
Indicator
State
PWR (in red)
ON
OFF
ERR (in red)
ON
Flashing quickly
Flashing twice
RUN (in green)
ON
Flashing
OFF
CANopen
Note
does.
Definition
3
4
5
6
7
8
0
0
0
0
0
0
Reserved
0
0
0
0
0
1
1
0
0
0
0
1
0
2
0
0
0
0
1
1
3
...
...
1
1
1
1
0
1
61
1
1
1
1
1
0
62
1
1
1
1
1
1
63
Description
Power-on is normal.
Power-on is abnormal. Check whether the
installation is proper.
The communication of the AC drive times out.
The CANopen address is set incorrectly.
The CANopen messages emergently.
The CANopen enters the "Operational" state.
The CANopen enters the "Pre-Operational" state.
The CANopen enters the "Stopped" state.
has the same bus topology and wiring method as CANlink
8. Peripherals and Options
DIP Switch
S2
S3
ON
ON
1
2
3
4
1
2
3
4
1
2
3
4
5
6
7
8
Baud
CANopen
address setting
rate setting
8
- 259 -

Advertisement

Table of Contents
loading

Table of Contents