K&R GT600-4T132G User Manual page 90

Ac drive high performance open and closed loop
Table of Contents

Advertisement

5. Quick Setup
If an encoder is used
Set encoder parameters
Perform motor auto tuning
5
Select command source
- 88 -
CONTINUE
CONTINUE
Para.
Parameter name
F1-27
Encoder pulses per revolution
1 to 65535ppr
F1-28
Encoder type
0: ABZ incremental encoder
2: Resolver
F1-30
A/B phase sequence of ABZ
encoder
0: Forward
1: Reserve
F1-31
Encoder installation angle
0.0° to 359.9°
F1-34
Number of pole pairs of resolver
1 to 65535 pairs of poles
F1-37
Auto-tuning selection
0: No auto-tuning
1: Asynchronous motor static auto-tuning 1
2: Asynchronous motor dynamic auto-tuning
3: Asynchronous motor static auto-tuning 2
NOTE: Motor won't rotate at this stage if choose 1 or 3, for
they are both static, while if choose 2 then motor will rotate,
so better disconnect load from motor shaft for safety.
Steps of auto-tuning:
1. Ensure the UVW connection between AC Drive and
motor is not disconnected by output contactor; if it is, then
manually handle with the output contactor;
2. Set F0-02 = 0 (operating panel), so that the key
can start the tuning procedure.
3. Set F1-37 = 1 or 2 or 3, press
will display letters "TUNE".
4. Press the key
RUN
tuning, it usually takes about 30 seconds to finish this auto-
tuning, wait until LED stops displaying "TUNE".
F0-02
Command source selection
0: Operating panel (keypad & display) (indicator 'LOCAL/
REMOT' turns OFF)
1: Terminal I/O control (indicator 'LOCAL/REMOT' turns ON)
2: Serial comms. (indicator 'LOCAL/REMOT' turns flashing)
Para.
Parameter name
Default
1024
0
0
0.0
1
0
, then LED on panel
ENTER
on panel, then motor starts auto-
1
Default
Commission
RUN
Commission

Advertisement