K&R GT600-4T132G User Manual page 188

Ac drive high performance open and closed loop
Table of Contents

Advertisement

6. Description of Parameters
6
- 186 -
Flexible connection
For the master in speed control, perform the following settings. Note that only the
setting of F8-15 can be modified.
Function Code
Parameter Name
Fd-00
Baud rate
A8-00
Selection of
point-point
communication
A8-01
Master and slave
selection
F0-10
Max. frequency
F8-15
Droop rate
F0-17
Acceleration time 1
F0-18
Deceleration time 1 0.0 to 6500.0s
For slave in speed control, perform the following settings. Note that only setting of F8-
15 can be modified.
Function Code Parameter Name
Fd-00
Baud rate
A8-00
Selection of
point-point
communication
A8-01
Master and slave
selection
Setting Range
Setting
0000 to 6039
Keep thousands position of
this parameter to the same
value for the master and
slave.
0: Disabled
1
1: Enabled
0: Master
0
1: Slave
5.00 to 500.00 Hz 50.00 Hz
Keep the same setting of
this parameter for the master
and slave.
0.00 to 10.00 Hz
1.00 Hz
0.0 to 6500.0s
Keep the same setting of
this parameter for the master
and slave.
Keep the same setting of
this parameter for the master
and slave.
Setting Range
0000 to 6039
0: Disabled
1: Enabled
0: Master
1: Slave
Setting
Keep thousands
position of this
parameter to the
same value for the
master and slave.
1
1

Advertisement

Table of Contents
loading

Table of Contents