K&R GT600-4T132G User Manual page 253

Ac drive high performance open and closed loop
Table of Contents

Advertisement

Table 8-2 Jumper descriptions of GT60IO1
Jumper
Description
J3
AO2 output selection:
voltage or current
J4
CAN terminal resistor
matching selection
S2
RS485 terminal
resistor matching
selection
S1
AI3, PT100, PT1000
selection
Setting of jumpers takes top view with main terminals at the bottom of the
Note
card as visual angle. Jumpers are silk-screened on the card.
When using CANlink or Modbus protocol for communication, match
terminal resistor to the end AC drives by setting jumpers J4 or S2. The
J4 or S2 of the middle AC drives must keep default state. If J4 or S2 is
set improperly, instable communication or communication failure will
be caused and Err16 or Err55 will be detected.
Meaning
Setting
Voltage: V to 10 V
Current: 0 to 20 mA
Matching terminal
resistor
Not matching
terminal resistor
ON
1 and 2 set to ON:
matching terminal
resistor
1 2
OFF
1 and 2 set to
OFF: not matching
terminal resistor
1 2
ON
AI3: 1, 2, 3 set to
ON
1
ON
PT1000: 4, 5, 6 set
to ON
1
ON
PT100: 6, 7, 8 set
to ON
1
8. Peripherals and Options
2
3
4
5
6
7
8
2
3
4
5
6
7
8
2
3
4
5
6
7
8
8
- 251 -

Advertisement

Table of Contents
loading

Table of Contents