Appendix A Standards Compliance
AC Drive Model
GT600-
4T18.5GB
GT600-4T22GB RWK 305-45-KL
GT600-4T30GB RWK 305-60-KL
GT600-4T37GB RWK 305-72-KL
GT600-4T45GB RWK 305-90-KL
GT600-4T55GB RWK 305-110-KL
GT600-4T75GB RWK 305-156-KS
GT600-4T90G
GT600-4T110G
GT600-4T132G
GT600-4T160G
GT600-4T200G
GT600-4T220G
GT600-4T250G
GT600-4T280G
GT600-4T315G
GT600-4T355G
GT600-4T400G
GT600-4T450G
12
- 322 -
dv/dt Reactor Installation
Connect a dv/dt reactor on the output side to reduce large dv/dt, protecting the motor
winding from insulation breakdown, lowering motor temperature and extending the motor
service life and meanwhile reduce interference on surrounding devices.
Selection of the dv/dt reactor (Schaffner)
dv/dt Reactor
Rated
Model
Current at
40° C (A)
RWK 305-45-KL
45
45
60
72
90
110
156
RWK 305-182-KS
182
RWK 305-230-KS
230
RWK 305-280-KS
280
RWK 305-330-KS
330
RWK 305-400-S
400
RWK 305-500-S
500
RWK 305-500-S
500
RWK 305-600-S
600
RWK 305-600-S
600
RWK 305-680-S
680
RWK 305-790-S
790
RWK 305-910-S
910
Mounting Dimensions (Unit: mm)
4-45A
Rated Motor
Rated
Power
Power (kW)
Inducance
Consumption
(mH)
(W)
18.5
0.131
22
0.131
30
0.098
37
0.082
45
0.065
55
0.053
75
0.038
90
0.032
110
0.026
132
0.021
160
0.018
200
0.015
220
0.012
250
0.012
280
0.01
315
0.01
355
0.009
400
0.007
450
0.006
G
D
A
I/O Terminal
Total
Selection
60
KL
-
-
60
KL
-
-
65
KL
-
-
70
KL
-
-
75
KL
-
-
90
KL
-
-
120
-
K S
-
140
-
K S
-
180
-
K S
-
220
-
K S
-
240
-
K S
-
330
-
-
S
340
-
-
S
340
-
-
S
380
-
-
S
380
-
-
S
410
-
-
S
590
-
-
S
740
-
-
S
C
F
E
B
(kg)
6.1
6.1
6.1
6.1
7.4
8.2
10.7
16
22
29
32
34
35
35
37
37
38
43
49