Function Code Parameter Name
A8-02
Selection of
action of the slave
in point-point
communication
A8-03
The slave received
data
F0-02
Command source
selection
F0-03
Main frequency
reference setting
channel selection
F0-10
Max. frequency
F0-17
Acceleration time 1 0.0 to 6500.0s
F0-18
Deceleration time 1 0.0 to 6500.0s
F8-15
Droop rate
A0-00
Speed/Torque
control selection
6. Description of Parameters
Setting Range
000 to 111
0: No
1: Yes
Units position: whether to
follow masters command
Tens position: whether to
send fault information to
master when a fault occurs
Hundreds position: whether
to alarm when it becomes
offline
0: Output frequency
1: Frequency reference
0: Operating panel control
(keypad & display)
1: Terminal I/O control
2: Serial comms.
0: Digital setting (non-
retentive at power down)
1: Digital setting (retentive
at power down)
2: AI1
3: AI2
4: AI3
5: Pulse reference
6: Multi-reference
7: Simple PLC
8: PID reference
9: Serial comms.
5.00 to 500.00 Hz
0.00 to 10.00 Hz
0: Speed control
1: Torque control
Setting
1
1
-
0
2
9
50.00 Hz
Keep the same
setting of this
parameter for the
master and slave.
Keep the same
setting of this
parameter for the
master and slave.
Keep the same
setting of this
parameter for the
master and slave.
1.00 Hz
0