6. Description of Parameters
6
+10V
Pot.
AI1
(2 kΩ)
0 to 10 V
GND
- 114 -
Step 2: Select a required curve for AI terminal.
F4-33 selects curve of AI1, AI2 and AI3 from the five curves, respectively. Curve 1, curve
2 and curve 3 are 2-point curves, set in group F4. Curve 4 and curve 5 are 4-point curves,
set in group A6.
The drive provides two AI terminals (AI1, AI2). An extra AI terminal (AI3) is provided by
the I/O extension card.
Function Code
Parameter Name
F4-33
AI curve selection
F4-17
AI1 filter time
F4-22
AI2 filter time
F4-27
AI3 filter time
F4-17, F4-22 and F4-27 set AI software filter time. If analog input is liable to interference,
increase this parameter to stabilize detected analog input. But too large a setting slows
response of analog detection. Set it correctly based on actual conditions.
Step 3: Select a required AI terminal as main frequency reference setting channel.
The AC drive provides two AI terminals (AI1, AI2). An extra AI terminal (AI3) is provided by
the I/O extension card.
Here takes each AI terminal as examples to show how to use AI terminal to control main
frequency reference.
Example 1: To make voltage input at AI1 to control frequency reference and correspond 2
to 10 V to 10 to 40 Hz, the settings are shown in the following figure.
Figure 6-16 Voltage input at AI1 to control frequency reference
Select AI1 as main
Setting
Para.
frequency reference
setting channel.
F4-13
20.0%
F4-14
F0-03 = 2
F4-15
10.00
F4-33 (units
F4-16
80.0%
position) = 1
F4-17
0.10
Select two-point
curve 1 for AI1
Note:
2 to 10 V corresponds to 20.0% to 80.0%.
100.0% corresponds to max. frequency (F0-10 = 50.00 Hz).
Setting Range
Curve 1 (2 points, see
Curve 2 (2 points, see
Curve 3 (2 points, see
Curve 4 (4 points, see
Curve 5 (4 points, see
Units position: AI1 curve selection
Tens position: AI2 curve selection
Hundreds position: AI3 curve selection
0.00s to 10.00s
0.00s to 10.00s
0.00s to 10.00s
Corresponding
percentage (%)
80.0
F4-16
2.00
60.0
40.0
F4-14
20.0
0.0
0.00 2.00 4.006.00 8.0010.00 AI (V)
F4-13
Default
)
321
to
)
to
)
to
)
to
)
0.10s
0.10s
0.10s
Final
F0-07 (units
frequency
position) = 0
reference
Select main frequency
reference as final
F4-15
frequency reference.