K&R GT600-4T132G User Manual page 334

Ac drive high performance open and closed loop
Table of Contents

Advertisement

Para. No.
Para. Name
F0-22
Frequency reference resolution
F0-23
Retentive of digital setting
frequency upon stop
F0-24
Motor parameter group selection
F0-25
Acceleration/Deceleration time
base frequency
F0-26
Base frequency for UP/DOWN
modification during running
F0-27
Command source + frequency
source
F0-28
Serial port comms. protocol
Group F1: Motor 1 Parameters
F1-00
Motor type selection
F1-01
Rated motor power
F1-02
Rated motor voltage
F1-03
Rated motor current
F1-04
Rated motor frequency
F1-05
Rated motor speed
F1-06
Stator resistance
F1-07
Rotor resistance
F1-08
Leakage inductive reactance
F1-09
Mutual inductive reactance
F1-10
No-load current
F1-27
Encoder pulses per revolution
F1-28
Encoder type
Setting Range
2
0, 1
0, 1
0 to 2
0, 1
000 to 999
0, 1
0, 1
0.1 to 1000.0 kW
1 to 2000 V
0.01 to 655.35 A (AC drive
power ≤ 55 kW)
0.1 to 6553.5 A (AC drive
power > 55 kW)
0.01 Hz to max. frequency
1 to 65535 rpm
0.001 to 65.535 Ω (AC drive
power ≤ 55 kW)
0.0001 to 6.5535 Ω (AC
drive power > 55 kW)
0.001 to 65.535 Ω (AC drive
power ≤ 55 kW)
0.0001 to 6.5535 Ω (AC
drive power > 55 kW)
0.01 to 655.35 mH (AC
drive power ≤ 55 kW)
0.001 to 65.535 mH (AC
drive power > 55 kW)
0.1 to 6553.5 mH (AC drive
power ≤ 55 kW)
0.01 to 655.35 mH (AC
drive power > 55 kW)
0.01 A to F1-03 (AC drive
power ≤ 55 kW)
0.1 A to F1-03 (AC drive
power > 55 kW)
1 to 65535
0: ABZ incremental encoder
2: Resolver
Appendix B Parameter Table
Default
Property
Page
2
-
0
0
0
0
-
000
0
0
Model
dependent
Model
dependent
Model
dependent
Model
dependent
Model
dependent
Auto-tuning
dependent
Auto-tuning
dependent
Auto-tuning
dependent
Auto-tuning
dependent
Auto-tuning
dependent
1024
0
12
- 331 -