2 Specifications and Functions
2.2.8 M-EXECUTOR Module (Motion Program Executor)
(4) Detailed Window
This section describes the M-EXECUTOR detail window.
• Program definition tab (M-EXECUTOR (list display) window)
The Program definition tab page registers a motion or sequence program to be executed.
Programs are executed according to the scan, in ascending numeric order.
A white cell can be set by the user, and a grey cell cannot be set by the user.
Individual display
Program definition number
No.
numeric order.
D
2-40
Shows M-EXECUTOR (individual display) window.
Sets the number of program definitions registered in the M-EXECUTOR Module.
The valid range is 0-16 (8 by default).
Shows the program execution order. The program will be processed according to the scan in ascending
Enables/disables the definition. Uncheck to enable the definition.