YASKAWA MP210 Series User Manual page 42

Machine controller
Table of Contents

Advertisement

2 Specifications and Functions
2.2.1 MP2100 Appearance/LED Indicators and Switch Settings
2. Use these switches to set the operating conditions for the JAPMC-MC2100-E/JAPMC-MC2102-E.
Mode Switch 1 (S1)
(a) Mode Switch 1 (S1)
No.
1
2
(b) Mode Switch 2 (S2)
No.
1
2
3
4
5
6
7
8
* Set the CP number allocated to the communication process logic port. When using two or more MP2100s,
(c) Reset Switch
This switch resets the MP2100.
This switch can be used to turn ON and OFF the MP2100 power without turning the host computer ON and
OFF.
2-10
Mode Switch 2 (S2)
ON
1
2
Name
Status
ON
Memory Clear
INIT
OFF
Normal operation
ON
User program stopped
STOP
OFF
User program running
Name
Status
ON
TEST
OFF
ON
MON
OFF
ON
CNFG
OFF
ON
INIT
OFF
ON
SUP
OFF
ON
STOP
OFF
SLOT1
- SLOT0
SLOT0
ON
- ON
ON
- OFF
OFF
- ON
SLOT1
OFF
- OFF
set a different CP number for each MP2100.
Reset Switch
Default
Function
Setting
OFF
Default
Function
Setting
System use
Normal operation
System use
Normal operation
Configuration mode
Normal operation
Memory clear
Normal operation
OFF
System use
Normal operation
User program stopped
User program running
CP4
CP3
CP2
CP1
Details
Set to ON to clear memory. The S registers and
M registers are cleared to zero. If this switch is
set to OFF, the program stored in flash memory
will be executed.
Set to ON to stop the user program before
debugging the program.
Details
Always set to OFF.
Always set to OFF.
Set to ON to execute self-configuration for
connected devices.
Set to ON to clear memory. The S registers
and M registers are cleared to zero. If this
switch is set to OFF, the program stored in
flash memory will be executed.
Always set to OFF.
Set to ON to stop the user program before
debugging the program.
Use to set CP number.

Advertisement

Table of Contents
loading

Table of Contents