Setting a GPI Output

You can configure the trigger type and action for each GPI
output.
GPI output via a network
On GPI outputs via a network, GPI control is performed
using serial tally protocol commands.
GPI outputs can be configured in the same way as parallel
output ports.
Note
This uses a serial tally port, hence the network port must
be configured for a serial tally port.
For details, see "Setting a Serial Tally" (page 345).
1
Open the Home > Setup > External Device > GPI
Output Assign menu (19105.41).
2
Select the target GPI output to set.
3
Press the [Source Target] button and select a control
panel (Panel 1, Panel 2) to handle the GPI output from
the pull-down list.
4
Press the [Trigger Type] button and select a trigger
type from the pull-down list.
Rising Edge: Trigger causes the output to go high
level and holds this state for the pulse width
duration.
Falling Edge: Trigger causes the output to go low
level and holds this state for the pulse width
duration.
Any Edge: When a trigger occurs, the output toggles
between high level and low level.
Status: The output toggles between high level and low
level according to the status.
NOP (No Operation): The trigger has no effect on the
output level.
5
Press the [Edit Action] button for [Action].
The [GPI Output Assign] window appears.
6
Select an action to set.
Select a tab to change the action type to display.
[PP/ME Key SS Recall] tab: Key snapshot actions
[PP/ME Key On] tab: Key on actions
[Make/Break/Device] tab: Error and device actions
Set the button for the target action to the on state.
7
Press [OK].
To set action preferences
You can set the timing, pulse width, and register to recall
by the action for a GPI output.
1
Select the target GPI output to set.
2
Press the [Action Details] button for [Reg/Timing/
Pulse Width].
The [Action Details] window appears.
3
Set the action preferences.
When a register recall action is selected
Press the [Register No.] button and enter a register
number in the numeric keypad window.
When [Rising Edge]/[Falling Edge]/[Any Edge]
trigger type is selected
Press the [Timing] button and select a timing (Field1,
Field2, Any) from the pull-down list.
When [Rising Edge]/[Falling Edge] trigger type is
selected
Press the [Pulse Width] button and enter a pulse width
(fields) in the numeric keypad window.
4
Press [OK].
Trigger type and actions list
When the trigger type is other than [Status]:
P/P Keyx SS Recall, M/E-x Keyx SS Recall, No Action
When the trigger type is [Status]:
P/P Keyx SS Recall, M/E-x Keyx SS Recall, No Action
P/P Keyx On, M/E-x Keyx On
Error Make, Error Break, Keep Make, Keep Break, Device
Recording
1) "M/E-x" is M/E-1 to M/E-5
"Keyx" is Key1 to Key8"
Testing trigger output
You can output a test trigger from a GPI output port.
Note
A trigger is not output when the trigger type is [Status].
1
Open the Home > Setup > External Device > GPI
Output Assign menu (19105.41).
2
Select the target GPI output to set.
3
Press the [Test Fire] button.