Control Panel Setup
Setting the Control Panel
Configuration

Assigning a Switcher Bank

You can select the switcher bank to assign to an M/E bank.
The M/E bank number indicates a physical position on the
control panel. On a control panel with two M/E bank rows,
the rows are numbered 1 and 2 from the back.
1
Open the Home > Setup > Panel > Config > M/E
Assign menu (19104.11).
2
Select the target M/E bank to set.
3
Press the [Assign] button and select a switcher bank
(M/E-1 to M/E-5, P/P) from the pull-down list.
To assign no switcher bank, select [- - -].
Setting Switcher Banks in Multi
Program 2 Mode
In multi program 2 mode, you can set main/sub for each
switcher bank assigned to an M/E bank.
You can select dedicated main, dedicated sub, or shared
main and sub.
1
Open the Home > Setup > Panel > Config > M/E
Assign menu (19104.11).
2
Select the target switcher bank to set.
3
Press the [Main/Sub] button and select main/sub from
the pull-down list.
Main: Dedicated main
Sub: Dedicated sub
Main&Sub: Shared main and sub
Chapter
Note
When dual M/E is enabled, you can set main and sub
to the shifted state and unshifted state of a switcher
bank assigned to two M/E banks.
The shifted/unshifted settings for dual M/E are
cleared.
For details about dual M/E, see "Setting Dual M/E"
(page 316).

Inhibiting Switcher Bank Operation

You can inhibit operation of switcher bank assigned to an
M/E bank.
1
Open the Home > Setup > Panel > Config > M/E
Assign menu (19104.11).
2
Select the target switcher bank to set.
3
Press the [Operation] button and select an operation
setting from the pull-down list.
Enable: Enable panel display and operation of the
switcher bank.
Disable: Enable panel display only, and inhibit
operation of the switcher bank.
Inhibit: Turn off panel display and inhibit operation
of the switcher bank.
Note
When selecting a region from the taskbar, switcher
banks with operation inhibited cannot be selected.

Inhibiting Key Operation

You can inhibit operation of key 1 to key 8 on each
switcher bank assigned to an M/E bank.
Key operations on the following control blocks can be
inhibited.
• Cross-point control block
• Transition control block
315