Gpi Output Setting (Gpi Output Assign Menu) - Sony MVS-8000 User Manual

With ccp-8000 series center control panel
Hide thumbs Also See for MVS-8000:
Table of Contents

Advertisement

4
Releasing the assignment of a GPI output port
Use the following procedure.
1
2
3
4

GPI Output Setting (GPI Output Assign Menu)

To set the trigger type and so on for each GPI output, display the DCU>GPI
Output Assign menu.
To display the GPI Output Assign menu
In Engineering Setup, select VF5 'DCU' and HF4 'GPI Output Assign.'
The GPI output port setting status appears in the status area.
Making DCU GPI output settings
Use the following procedure.
1
276
Setup Relating to DCU
To confirm the selected setting, press [GPI Output Set].
This confirms the selection, which is reflected in the status area.
In the DCU>Output Config menu, select what the setting applies to (DCU1
or DCU2) from the <DCU Select> group.
In the <Parallel Output Assign> group, if [GPI Output] is on, press it to
turn it off.
Turn the knobs to select the slot and port to which the setting applies.
Knob
Parameter
1
From Slot
2
From Port
3
To Slot
4
To Port
In the <Parallel Output Assign> group, press [No Assign].
In the DCU>GPI Output Assign menu, using any of the following methods
select what the setting applies to.
• Press directly on the list appearing in the status area.
• Press the arrow keys to scroll the reverse video cursor.
• Turn the knob to make the setting.
Adjustment
First port slot
First port number
Last port slot
Last port number
Setting values
2 to 6
1 to 54
2 to 6
1 to 54