Setup Relating to Operations From the
Control Panel

Overall Control Panel Settings (Config Menu)

To carry out the overall control panel settings, use the Panel>Config menu.
To display the Config menu
In the Engineering Setup menu, select VF2 'Panel' and HF1 'Config.'
The status area shows the "Bank numbers 1 to 4" (physical locations) of the
operating banks, the allocated operating bank names, and whether or not
operation is enabled.
Interchanging the operating bank order or disabling operation
Use the following procedure.
1
2
248

Setup Relating to Operations From the Control Panel

In the Panel>Config menu, select the Bank you want to set, using either of
the following methods.
• Press directly on the status area display.
• Press the arrow keys to scroll the reverse video cursor.
• Turn the knob.
Knob
Parameter
Adjustment
1
Bank
Select the position of the operating bank
you want to set
The Bank selection here indicates the physical position on the control
panel, numbering from the top as the 1st Row, 2nd Row, 3rd Row, and 4th
Row.
On the MKS-9011 1M/E Control Panel only the 1st Row is valid. On the
MKS-9012 2M/E Control Panel, only the 1st Row and 2nd Row are valid.
Select the operating bank that you want to assign to the selected Bank
number in the <M/E Assign> group.
The status area shows the interchanged state of the operating banks.
Notes
• It is not possible to assign the same M/E logical bank to more than one
physical bank. Be sure to make different M/E assignments.
Setting values
1 to 4