Administer user profiles
Two default user accounts are available on the NE. These default user accounts can
not be deleted. For security reasons the password for the default user accounts
should be changed. See
Table 4
User Name
initial
Craftperson
Supported operations by the profiles:
230
• Maximum Length - Password shall not exceed twenty characters in length
• Composition - Passwords must be composed of full ASCII characters (UPPER
case, lower case, numeric, and special characters).
Table 4
Default user account profiles
• Administrator profile: All the NE parameters are accessible both in writing and
reading mode. Also the management of user accounts is allowed (create/delete
user accounts and change of all passwords).
• Operator profile: Full reading access to NE parameters. For writing mode the
following parameters are allowed to change:
− ATPC configuration (enabled, disabled)
− Performance Monitoring management
→ start/stop CD
→ threshold tables configuration
→ reset
→ archiving (only for NMS system)
Supported for all the types of Performance Monitoring (Radio Hop/Link, E1,
Received Power Levels, ....)
− NTP protocol:
→ Enabled/Disabled
→ NTP main server address configuration
→ NTP spare server address configuration
• CraftPerson profile: This operator has the same privileges of the Administrator,
but cannot manage the user accounts
• Viewer profile: This operator can only read and can change his own password.
for default user account details.