WebEML User Manual
67 Open and run performance monitoring
67.1 Purpose
This chapter provides the procedures to open and run performance monitoring (PM)
for the 9500 MPR.
67.2 General
The Performance Monitoring Suite provides the ability to gather statistical data on
Ethernet or Radio ports and RSL History to determine the quality level of ports over
time.
PM counters are arranged in the following panels:
PM data is collected for 15-min and 24-h time periods. One current register and
ninety-six history reports are available for a 15-min period. One current register and
eight history reports are available for a 24-h time period.
PM data is considered suspect when one or more of the following conditions occurs
during the collection period. When data is suspect, it is flagged in the PM view.
The 15-min PM data is stored in the History Data report only when errors are
recorded.
• Ethernet Statistics
• Radio PM
• Adaptive Modulation PM
• PDH PM
• SDH PM
• RSL History
• The elapsed time deviates more than 10/900 s from the nominal time for the 15-
min or 24-h collection period.
• There was loss of PM data in equipment, including PDH/SDH Access Board
missing.
• Performance counters were reset during collection period.
• PM was activated during the collection period.