Release 7.0.0 3DB 19286 ACAA Issue 01
Configure radio parameters
73. Configure the Low Voltage Alarm for the MPT-HQAM
Figure 657
MPT-HQAM Maintenance tab
74. Configure the Low Voltage alarm:
876
ii. Enter and confirm the new passphrase.
iii. Click Apply in the Edit passphrase window.
Open the appropriate radio main view depending on your radio configuration
and select the Maintenance tab; see
i. Select the Enabled check box.
ii. In the Threshold field, configure the threshold voltage for the alarm using
the arrows. The threshold can be configured in 0.5 V increments.
iii. Click Apply.
The clear alarm hysteresis is 3V from the set threshold value.
The operator should take care in the configuration of the Low Voltage Alarm
Threshold of the nominal voltage of the equipment.
WebEML User Manual
Figure
657.