Release 7.0.0 3DB 19286 ACAA Issue 01
WebEML User Manual
5. Select CPI#[1-6] in the resource tree area.
6. Select CPI#[1-6] in the resource tree area.
7. In the User Label field, enter the alarm input label.
8. Select the External inputs Polarity radio button, Active Low or Active High.
9. Click Apply.
Figure 32
External alarm inputs provisioned
10. Close the AUX Main View window.
To provision external alarm outputs
1. Select MSS-4/AUX slot #4 or MSS-8/AUX slot #8 in the resource tree area.
2. Double-click on the blue AUX Card.
The External Points Resource List Table updates. See
This selection should also highlight the MSS/AUX card in blue on the graphical
representation of the MSS shelf in the resource list area.
Administer external alarm points on an Auxiliary
card
Figure
32.
113