Release 7.0.0 3DB 19286 ACAA Issue 01
WebEML User Manual
Note: The Channel #1 Rx Freq (KHz) field displays the Rx RF Frequency and is the result
of the following calculation:
RX Frequency = TX Frequency - Shifter Frequency
Note: In a Protected MPT-HL configuration, the Main and Protect MPT-HL cards use the
same CT screen. The parameters on the Spare (Channel #0) part of the screen is a mirror
image of the Main (Channel #1) part of the screen. Most Channel #0 fields will be
automatically populated to match Channel #1, except the transmit power. The transmit
power must be configured independently.
11. Select an action.
12. Provision the MPT-HL 1+1 spare radio channel
v. In the Supported Modulation panel, choose all the modulation schemes to
be used by the adaptive modulation. The schemes must be contiguous.
vi. Click on the Data Help button in the Shifter panel. The MPT-HL Shifter Data
Help window opens.
vii. In the Data Help window, double-click on the table row for the desired shifter
value.
viii. When the MPT-HL is connected to the MSS shelf, the Channel #1
TxFreq(KHz) field is automatically populated. If the MPT-HL is not
connected, enter the TX RF Frequency within the allowed range.
ix. If the MPT-HL is not connected, enter the Rx RF Frequency within the
allowed range.
x. Enter the MPT-HL radio channel User Label, if applicable.
xi. Click Apply.
a. To
Provision the MPT-HL 1+1 spare radio
b. To
Provision the MPT-HL manual transmit power level
step 16.
c. To
Provision the MPT-HL Automatic Transmit Power Control
step 19.
d. To perform additional procedures
go to step 1.
Open the appropriate radio main view depending on your radio configuration
and select the Settings tab; see
Configure radio parameters
channel, go to step 13.
To administer the MPT-HL
Figure
599.
(RTPC), go to
(ATPC), go to
transceiver,