Pps: Setting Pps Pulse Properties - Magellan ProFlex 500 Reference Manual

Table of Contents

Advertisement

Set Command Library

PPS: Setting PPS Pulse Properties

Function
Command Format
Relevant Query
Command
158
This command is used to set the period, offset and GPS-
synchronized edge of the PPS pulse.
Syntax
$PASHS,PPS,f1,f2,c3[*cc]
Parameters
Parameter
PPS time period, a multiple or
f1
fraction of 1 second.
• 0: 1 PPS disabled
f2
Time offset in milliseconds.
GPS-synchronized edge code:
c3
• "R" for rising edge
• "F" for falling edge
*cc
Optional checksum
Example
Setting the PPS signal to a period of 2 seconds, with an offset
of 500 ms and a GPS-synchronized rising edge:
$PASHS,PPS,2,+500,R*74
$PASHQ,PPS
Description
0 to 1, with 0.1-sec
increments
1 to 60, with 1-sec
increments
± 999.9999
R, F
*00-*FF
Range
Default
0
0
R

Advertisement