Applying Commands Through Tcp/Ip - Magellan ProFlex 500 Reference Manual

Table of Contents

Advertisement

Applying Commands Through TCP/IP

Setting the
Ethernet Port
Running a Single Command at a Time
• Tap your command directly in the combo box using FAST
Survey's virtual keyboard. The keyboard appears
automatically when you tap inside the box.
• Tap
after you have typed the command line.
• Tap on the Send button to send the command to the
receiver. The command line as well as the response line(s)
then appear at the bottom of the screen.
Running a Series of Commands
First of all, you need to create a TXT file containing all the
commands you want the receiver to run. Save the file to the
"MyDevice/FAST Survey/Data/" folder. Then do the following:
• Use the Send File button in the upper part of the window
to select the TXT file and send it to the receiver.
• Once the receiver has executed all the commands
included in the file, a new window is displayed listing
each of the commands run in the receiver as well the
resulting receiver response line(s).
• Tapping
will take you back to the command window.
The ProFlex 500 receiver can be remotely controlled through
its Ethernet port.
By default, the Ethernet port is on and a default configuration
allows you to connect to the receiver via a secured TCP/IP
connection using these default credentials: "magellan for
login and "password" for password. However, if the Ethernet
port is off and the TCP/IP function has been deactivated or
needs new settings, follow the instructions below to set the
Ethernet port.
Run the following three $PASH commands through one of the
receiver's serial ports. The syntax of the commands
mentioned below is fully described in the Set Command
Library chapter.
The choices in the last two commands should be made in
collaboration with your local network administrator or Internet
Service Provider (ISP).
Using Serial Commands
89

Advertisement

Table of Contents
loading

Table of Contents