PWR,PAR: Power Management

Function
Command Format
Relevant Query
Command
This command is used to set the voltage thresholds triggering
low-power alarms.
Syntax
$PASHS,PWR,PAR,f1,f2[*cc]
Parameters
Parameter
Battery voltage threshold, in volts, trigger-
f1
ing a low-battery alarm
External power voltage threshold, in volts,
f2
triggering a low-power alarm
*cc
Optional checksum
Example
Setting the thresholds to respectively 7 and 9 V:
$PASHS,PWR,PAR,7,9*41
$PASHQ,PWR
Description
Set Command Library
Range
Default
6.7-8.4
6.8
9.0-28.0
9.1
*00-*FF
-
161