RAW: Raw Data Logging Settings

Function
Command Format
Response Format
This command is used to query the raw data recording
parameters.
Syntax
$PASHQ,RAW[*cc]
Syntax
(Through an example):
PER:020.00 ELM:10
RAW: MPC PBN SNV SNG SNW SAL SAG SAW ION DAT BAUD
PRTA: ON OFF OFF OFF OFF OFF OFF OFF OFF OFF 6
PRTB: ON OFF OFF OFF OFF OFF OFF OFF OFF OFF 6
PRTC: OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF 1
PRTF: ON OFF OFF OFF OFF OFF OFF OFF OFF OFF 6
PRTI: ON OFF OFF OFF OFF OFF OFF OFF OFF OFF 1
MEMM: OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF 1
MEMU: OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF 0
Parameters
Parameter
PER
Output rate, in seconds
Elevation mask used in data recording &
ELM
data output
RAW
Raw data type
PRTA
PRTB
Serial port
PRTF
PRTC
Bluetooth
PRTI
Ethernet
MEMM
Labels for memories M (MEMM) and U
MEMU
(MEMU)
For serial port: Baud rate code
BAUD
For other devices, "0" if not available, else
"1"
Code
Baud Rate
0
300
Description
Code
Baud Rate
8
57600
Query Command Library
Range
0.00-999.00
0-90
MPC, PBN, SNV,
SNG, SNW, SAL,
SAG, SAW, ION, DAT
ON, OFF
ON, OFF
ON, OFF
ON-OFF
0-15 (see table
below)
0-1
243